How A Coriolis Mass Flowmeter Works
Leave a message
When gas passes through the pipe of a Coriolis mass flowmeter, it passes between two materials of different temperatures. The temperature difference between the two materials generates an electrical potential difference, the magnitude and direction of which is related to the gas's flow rate and density. When a potential difference sensor measures this potential difference, it converts the signal into a digital signal and transmits it, along with the signal from the temperature sensor, to a computer or other controller. The controller uses these signals to calculate the gas's mass flow rate and then displays the result on the computer screen or outputs it to another device.
Specifically, when gas passes through the Coriolis mass flowmeter, the temperature difference between the thermocouple and the cold junction generates an electrical potential difference. The magnitude and direction of this potential difference depend on the gas's flow rate and density. The potential difference sensor converts this potential difference into a digital signal and transmits it, along with the signal from the temperature sensor, to a computer or other controller.
In computers or other controllers, based on the physical properties of the gas, various formulas and algorithms can be used to calculate the gas's mass flow rate. Formulas involving the fluid's dynamic pressure and temperature difference are a commonly used method.
Fluid dynamic pressure refers to the pressure generated by gas flow and can be calculated by measuring the output signal of a fluid dynamic pressure sensor. Temperature difference refers to the temperature difference between the thermocouple and the cold end, and can be measured by a temperature sensor.
Based on the measured values of these parameters, formulas and algorithms can be used to calculate the gas mass flow rate. For example, for gas flowing in a pipe, the mass flow rate can be calculated using the following formula:
Q = A × ρ × V
Where Q represents the gas mass flow rate, A represents the cross-sectional area of the pipe, ρ represents the gas density, and V represents the gas flow rate.
To achieve more accurate measurement results, Coriolis mass flowmeters are typically calibrated and adjusted. Calibration can be performed in a laboratory or other controlled environment, typically using standard gases and precision instruments. Adjustment can be performed in the field and typically requires adjustment and optimization based on actual conditions.