Coriolis Mass Flowmeter Maintenance And Care

1. Regular Calibration and Parameter Verification
Zero Calibration

Perform zero-point calibration every three months or six months to ensure the displayed value is zero when there is no flow. Calibration should be performed through the transmitter interface when the fluid is completely still.

Calibration frequency should be increased in high-temperature or pressure-fluctuating environments.

Dynamic Parameter Calibration

Use a standard fluid (such as water or a medium of known density) to calibrate parameters such as mass flow rate and density, ensuring measurement accuracy ≤±0.1%.

2. Cleaning and Anti-clogging Management

Measuring Tube Cleaning

Clean the measuring tube regularly to remove residual dirt or deposits (such as sludge and particles) to prevent blockage or adhesion that may cause zero-point drift.

For high-viscosity or solid-containing media, it is recommended to clean it every three months using a soft cloth or a non-corrosive cleaning agent.

Pipeline and Filter Maintenance

Check the cleanliness of upstream and downstream pipelines. Install a pre-filter to trap impurities and clean the filter regularly. 3. Key Component Inspection and Maintenance
Sensor and Connection Inspection

Check the sealing of flange connections monthly to ensure there are no leaks. Tighten any loose bolts to prevent stress, distortion, or vibration interference.

Inspect the sensor housing for corrosion or wear, and apply an anti-corrosion coating if necessary.

Cable and Power Supply Maintenance

Verify the signal cable for aging or damage, and measure the power supply voltage stability (±10% fluctuation range).

4. Environmental and Operating Condition Control

Vibration and Electromagnetic Interference Protection

Keep away from vibration sources such as pumps and compressors (≥5 meters). Install a shock-absorbing bracket if necessary.

Keep electromagnetic interference sources such as transformers and high-power equipment away from the flowmeter.

Pressure and Temperature Management

Monitor pipeline pressure fluctuations (recommended ≤80% of rated pressure) to prevent cavitation or flashing.

In high-temperature operating conditions, install a heat sink to prevent sensor overheating (>80°C) and measurement drift. 5. Software and Spare Parts Management
Software Updates and Data Backup

Regularly upgrade transmitter firmware to optimize algorithms or fix system vulnerabilities.
Back up key parameters (such as calibration data and density compensation coefficients) to prevent accidental loss.
Spare Parts Storage and Replacement

Maintain a supply of vulnerable parts, such as sensors and drive coils, and promptly replace aging parts (such as sensors with a service life greater than 10 years).
In summary: Coriolis mass flowmeter maintenance should focus on regular calibration, combined with comprehensive measures such as cleaning, anti-blocking measures, component inspection, and environmental control to ensure long-term stable operation.