CMASS025LD Low-pressure Liquid Nitrogen Coriolis Mass Flowmeter
Precise Cryogenic Measurement, Mastery of Nitrogen – Low-Pressure Coriolis Mass Flow Meter Designed for Cryogenic Liquid Nitrogen Applications.
Description
CMASS025LD Low-pressure liquid nitrogen Coriolis mass flowmeter


Precise Cryogenic Measurement, Mastery of Nitrogen – Low-Pressure Coriolis Mass Flow Meter Designed for Cryogenic Liquid Nitrogen Applications.
In fields such as air separation, semiconductors, cryogenic physics, and scientific research, accurate and reliable mass flow measurement of low-pressure cryogenic liquid nitrogen is crucial for ensuring process safety and efficiency. Conventional flow meters often struggle with weak signals and unstable measurements under low-pressure cryogenic conditions. Leveraging profound expertise in cryogenic technology, Chengdu Keli Deep presents a Coriolis mass flow meter specifically optimized for cryogenic media like low-pressure liquid nitrogen, providing you with a reliable solution.
Key Challenges & Solutions
1. Tackling Measurement Challenges in Low-Pressure Cryogenic Media with High Precision
- Challenge:Liquid nitrogen operates at extremely low temperatures (-196°C), and its density decreases further under low-pressure conditions, making signal acquisition difficult for conventional instruments and compromising measurement accuracy.
- Solution: Featuring an "inverted triangle" sensor design optimized for cryogenic environments and 316L cryogenic measurement tubes paired with high-sensitivity sensors, our flow meter maintains exceptional zero-point stability and ±0.2% high measurement accuracy even in low-pressure, ultra-low-temperature conditions, delivering direct mass flow output.
2. Compatibility with Low-Pressure Systems for Smooth Operation
- Challenge: Low-pressure systems have limited driving force and are highly sensitive to pressure loss caused by flow meters. Excessive pressure loss can disrupt normal system operation.
- Solution:The inverted triangle tube design ensures minimal pressure loss, making it perfectly suited for low-pressure liquid nitrogen systems without any adverse impact on the process. The smooth measurement tube design eliminates additional pressure loss.
3. Integrated Design Simplifying Cryogenic System Architecture
- Challenge:Cryogenic systems are complex and maintenance-intensive. Multiple instruments are often required to measure parameters such as flow and density, increasing costs and potential failure points.
- Solution:One instrument for multi-parameter measurement. Simultaneously outputs mass flow, density, and temperature signals, easily integrating into control systems via RS485 and 4-20mA interfaces. Equipped with a local display for convenient on-site monitoring and debugging.
4.Adapted for Harsh Environments, Stable, Reliable, and Maintenance-Free
- Challenge:Low temperatures can easily cause electronic component failures, and explosion-proof requirements may be necessary for certain environments.
- Solution:Powered by 24VDC and certified with Ex explosion-proof ratings, our flow meter is suitable for hazardous areas. With an IP67 high protection rating, the transmitter withstands harsh environmental conditions such as moisture and dust. The absence of moving parts ensures long-term stability and low maintenance in cryogenic applications.
Core Advantages
- Expert in Cryogenic Low-Pressure Applications:Designed specifically for low-pressure cryogenic media like liquid nitrogen.
- High-Sensitivity Sensors:Excellent performance in low-pressure, low-flow measurements.
- Direct Mass Measurement: Unaffected by temperature and pressure variations.
- Extremely Low Pressure Loss: Optimized flow path ideal for low-pressure systems.
- High Accuracy and Repeatability:±0.2% accuracy ensures process consistency.
- Multi-Function Integration:One device serves multiple purposes, saving space and cost.
- Durability and Maintenance-Free Operation:No moving parts, 316L construction, and long service life.
- Smart Communication and Display: RS485 and 4-20mA outputs with local display.
Model and diameter
|
Model |
Nominal diameter |
Medium temp. |
Max.W.P |
Max. flow-rate |
||
|
inch |
mm |
kg/min |
Lb/min |
|||
|
CMASS025 |
1" |
DN25 |
-200℃~+150℃ |
≤4MPa |
200 |
440 |
|
Characteristic |
Description |
|
Certification: Transmitter & Sensor Assembly |
CCS Certification, CPA, Explosion proof certificate(ex) |
|
Power Supply |
220VAC/24VDC Self-adaption |
|
Output signal |
Hart,4 to 20mA current loop active,Modbus RTU/RS-485, Pulse active |
|
Display;Operate |
3-line backlight; Touch key control |
|
Protection grade |
IP66,IP67 |
|
Housing material |
304 stainless steel, ZL401 (Transmitter) |
|
Electrical connection |
1/2 NPT,M20*1.5 |
|
Measuring Tube Material;Wetted Parts Surface Finish |
316L (default), titanium/Ha C alloy/tantalum (optional); polishable. |
|
Process connection |
Thread,Flange,Sanitary high-speed interface |
|
Accuracy |
±0.1%,±0.15%, ±0.2%, ±0.5 %, ±1.0% |
|
Transmitter software |
CLS100 (default), optional CLS200, CLS300 |
|
>Operating language display |
Chinese, English, Russian |
|
>>Other certifications |
Explosion proof certificate, SIL, CCS, 3-A, EAC |
Typical Application Scenarios
- Liquid nitrogen supply systems in research laboratories
- Low-pressure liquid nitrogen cooling control in semiconductor manufacturing
- Low-pressure liquid nitrogen transport in air separation equipment